Model: Supported standards: Function:
ZIEGLER FT-1000 Klebkraftprüfgerät - Ziegler FT-1000
  • FINAT* FTM 1

  • FINAT* FTM 2

  • FINAT* FTM 3

  • FINAT* FTM 9

  • FINAT* FTM 10

  • FINAT* FTM 11

  • Afera**

    • Horizontal tensile testing machine for adhesive strength tests
    • Sample table as a movable clamp with constant feed
    • Fixed clamp with rigid coupling to the load cell
    • Measurement of separation force and peel strength
    • Optional peel angle of 180° or 90°
    • Control via operating elements and FTSOFT software

    More information...

    ZIEGLER FT-1000H Klebkraftprüfgerät - Ziegler FT-1000H
  • FINAT* FTM 1

  • FINAT* FTM 3

  • FINAT* FTM 10

  • FINAT* FTM 11

  • Afera**

    • Horizontal tensile testing device for adhesive strength tests
    • Heated sample table
    • Sample table as a movable clamp with constant feed
    • Fixed clamp with rigid coupling to the load cell
    • Measurement of separation force and peel strength at a peel angle of 180°
    • FT-1000H can be used in stand-alone operation
    • Average value measurement at a specified speed

    More information...

    ZIEGLER FT-2000 Klebkraftprüfgerät - Ziegler FT-2000
  • FINAT* FTM 1

  • FINAT* FTM 2

  • FINAT* FTM 3

  • FINAT* FTM 9

  • FINAT* FTM 10

  • FINAT* FTM 11

  • Afera**

    • Speed ​​is precisely maintained
    • Adjustable speeds: 50/300/1000 mm/min and pull-off speeds from 10 mm/min to 10 m/min
    • Standard pull-off speed is 300 mm/min
    • Optional motor-operated 90° pull-off available

    More information...

    ZIEGLER FTM 180
    Peel tester - Ziegler FTM 180
  • FINAT* FTM 1

  • FINAT* FTM 3

  • FINAT* FTM 9

  • FINAT* FTM 10

  • FINAT* FTM 11

    • For vertical 180° pull-off tests and loop tack measurements
    • Up to 9 individually vertically movable force transducers
    • Pull-off speeds: 300 mm/min and 10 m/min
    • Manually movable sample table

    More information...

    ZIEGLER FTM-Multi
    Klebkraftprüfgerät - Ziegler FTM-Multi
  • FINAT* FTM 1

  • FINAT* FTM 2

  • FINAT* FTM 3

    • Sample pull-off at angles of 90° and 180° possible
    • 6-way tensile testing device
    • Individually vertically movable force transducers
    • Horizontally movable sample table
    • Pull-off speeds: 10-1000 mm/min

    More information...

    ZIEGLER HS-300 High Speed Release Tester - Ziegler HS-300
  • FINAT* FTM 4

    • High Speed ​​Release pull-off testing device
    • Developed to measure the release force during fast pulls
    • Tailored to the requirements of manufacturers, processors and users of adhesive composite materials

    More information...

    ZIEGLER FTM-8 Shear tester - Ziegler FTM-8
  • FINAT* FTM 8

    • Specially designed for testing and shear tests according to the FINAT FTM 8 test method
    • Testing of up to 10 samples simultaneously possible
    • Built-in stopwatches for measuring the shear time (0.01 to 9999.99 hours)
    • No external power supply of the testing device required

    More information...

    ZIEGLER FTM-8-96 Schertester FTM 8-96
  • FINAT* FTM 8

    • Designed according to the principle of a pull-out "pharmacist's cabinet"
    • 96 test stations can be integrated into the laboratory in a clear and space-saving manner
    • Time measurement via microswitch contacts
    • Test stations can be loaded with weights from 200 g to 2 kg

    More information...

    ZIEGLER SAFT-24
    Schertester - Ziegler SAFT-24
  • Afera** 5013 Shear Adhesion Failure Temperature (SAFT) of Adhesives Tapes (with heat)

  • Afera** 5012 Self Adhesive Tapes, Measurement of Static Shear Adhesion (without heat)

  • PSTC-17*** Shear Adhesion of Pressure Sensitive Tape

  • ASTM**** D 4498, Standard Test Method for Heat-Fail Temperature in Shear of Hot Melt Adhesives

  • FINAT* FTM 8 (without heat)

    • For vertical shear testing of self-adhesive materials on test panels
    • Testing the ability to withstand high temperatures
    • Shear force testing with constant increasing temperature according to PTSC-17
    • Specimens are tested in a heating cabinet for temperature control and monitoring

    More information...

    ZIEGLER STH-10 Schertester - Ziegler STH-10
  • Temperature-controlled shear tests,
    no specific test methods

    • Temperature-controlled shear tests up to a maximum of 50°C
    • Testing of up to 10 samples possible at the same time
    • Built-in hour counter for measuring the shear time (0.01 to 9999.99 hours)

    More information...

    ZIEGLER LUMI 12 Luminescence Measurement Device LUMI 12
  • Luminescence
    450 – 750nm
    5-12 LAETUS according to
    CIBA GEIGY whiteness index

    • Compact table device
    • UV light sensor for measuring luminescence
    • Wavelength range: 450 – 750 nm
    • Measurement and analog display of the luminescence value
    • Measuring range: 5-12 LAETUS according to CIBA GEIGY whiteness
    • Suitable for:
      • Paper
      • Plastic materials
      • Coatings
      • Similar test materials

    More information...


    Device accessories

    Here you will find an overview of our device accessories.

    ZIEGLER hand roller ZIEGLER Handroller
  • Hand roller according to FINAT specifications

  • Diameter of the roll:
    85 ± 2,5 mm

  • Pressure roller that meets the FINAT* specifications. The pressure roller can apply the pressure required for these specifications and is designed in such a way that operating errors are excluded.

    More information...

    Peel Adhesion 90°
    Rollenschälvorrichtung
  • FINAT FTM 2

  • The peel strength according to Finat FTM 2 is defined in the same way as the peel strength according to Finat FTM 1, but with a peel angle of 90°. The peel strength of label material depends on the peel angle. Often there is a minimum peel strength at a peel angle of 90°. Measurement type I (90°) is therefore best used if the label material tears with measurement type A (180°) and if a measurement result without a material tear is required. The roller peeling device (additional equipment) is required to carry out measurement type I.

    More information...


    * Féderation internationale des fabricants et transformateurs d'adhésifs et thermocollants sur papiers et autres supports.
    ** Afera, the European Association for the Self Adhesive Tape Industry